    The Solution to Multi-point Automated Hipot Dielectric Testing

    Click  here to download the data sheet

     

     

    Have a question about the 948i Switching System? Click Here to Ask An Expert!

    Unlimited Scanning Possibilities with 7KV, 10KV, 15KV, 40A, & 70A Switching Modules

    When a single 948i Hipot High Voltage Switching System is combined with a Vitrek automated Hipot tester, up to 48 test points can be scanned for high voltage isolation - multiple units work together to increase your test point count. Combine two 948i's for 96 points of switching capability or ten units for 480 point capacity. Expansion possibilities are virtually unlimited. And with voltage switching capability up to 15,000 volts or current switching as high as 70 amps - the 948i can handle just about any test requirement that comes along.

    Modular Configuration Assures that Your Requirements are Satisfied

    The 948i is easily configured to meet your specific test needs. For starters, select the voltage rating and number of HV switching channels desired.  In addition to hipot and IR - do you also need to do continuity or low resistance? How about LCR measurement or 4-wire resistance?  The MX modules can be added or customized to allow additional measurement equipment to access the matrix.

    In a typical application each test point needs to be bi-polar (high for some tests and low for others), multiply the number of test points in the DUT by two and that is how many relay channels you will need.

    A single 948i can accommodate 24 bi-polar test points with three 8 channel cards connected to the high voltage bus and with three 8 channel cards connected to the return bus. To add continuity or low resistance measurement capability to the system, an MX-2 card will allow you to use the matrix for either hipot or low  resistance testing.  For higher test point counts additional 948i's can be connected to accomplish the task.  If you have any questions about configuring one or more 948i's Vitrek applications assistance is just a phone call or a click away.

     

     

    Need help configuring your 948i? Click Here to Ask An Expert!

    Set-Up is a Snap

     

    The 948i is fast and easy to use so there is no excuse for using the hit-and-miss manual probing method of high voltage multi-point Hipot testing. The 948i increases operator safety by reducing exposure to high test voltages while enhancing product quality and reliability. Consistent and repeatable hipot test results are automatically documented making it simple to prove compliance with ISO 9000 quality standards.

    Setting up the switching pattern for the 948i is a snap. The standard GPIB interface port allows the system controller to download, verify and activate any desired switching profile you can dream up. Or if you prefer, an optional RS232 interface is also available. And if programming code is not your ideal way of spending the day, Vitrek QuickTest graphical software can get you up and running in no time at all. For those who are looking for a stand alone system the 948i can be controlled directly by the Vitrek 944i in a PC free environment. So, no matter how you like it - Vitrek puts you in control of your automated high voltage test requirement.

    Now that there are no more excuses, isn't it about time you automated your high voltage test application?

    Features/Benefits

              Voltage Switching Ratings to 7KV, 10KV or 15KV

              Current switching to 40 or 70 Amps

              Reduces operator exposure to high voltage

              Improves test quality, consistency and repeatability

              Enhances end product quality and reliability

              Scans up to 48 points with single compact unit

              GPIB Standard - RS232 no extra charge

              May be controlled directly by Vitrek Hipot Tester

              Available QuickTest™ graphical programming software

              CE mark certified to EN 61010

              Made in the USA

     

    The below is a schematic representation of two 8 channel scanning modules. One is connected to the high voltage output of the tester and the other to the return sense. This configuration provides bi-polar test capability for the 8 test points. Additional cards and units can be added for greater capacity.

    948i Switch Card Diagram

    Switch Card Specifications

     

    HV7 Series - 7KV High Voltage Switch Card

     
    Maximum Switching Voltage 7kVDC, 5kVAC RMS 50-60Hz
    Maximum Switching Current 2A DC or RMS AC
    Maximum Switching Power 50 Watts
    Relay Switching Time 4mS (from applied coil current)
    Relay Configuration Form A, SPST Normally Open

    HV7 Series Switch Card Configuration:

    HV7-8R 7KV Single input bus 8 output relays terminated in Red HV terminals,

    HV7-8B 7KV Single input bus 8 output relays terminated in Black HV terminals

    HV7-4R 7KV Single input bus 4 output relays terminated in Red HV terminals

    HV7-4B 7KV Single input bus 4 output relays terminated in Black HV terminals

    HV7-MX2 Dual input Single output MUX Card (selectable HV or continuity capability)

     

    HV10 Series - 10kV High Voltage Switch Card

    Maximum Switching Voltage 11kVDC, 8kVAC RMS 50-60Hz
    Maximum Switching Current 2A DC or RMS AC
    Maximum Switching Power 50 Watts
    Relay Switching Time 4mS including debounce
    Relay Configuration Form A, SPST Normally open

    HV10 Series Switch Card Configuration:

    HV10-8R 10KV Single input bus 8 output relays terminated in Red HV terminals,

    HV10-8B 10KV Single input bus 8 output relays terminated in Black HV terminals

    HV10-4R 10KV Single input bus 4 output relays terminated in Red HV terminals

    HV10-4B 10KV Single input bus 4 output relays terminated in Black HV terminals

    HV10-MX2 Dual input Single output MUX Card (selectable HV or continuity capability)

     

    HV15 Series High Voltage Switch Card:

    Maximum Switching Voltage 15kVDC, 10kVAC RMS 50-60Hz
    Maximum Switching Current 2A DC or RMS AC
    Maximum Switching Power 50 Watts
    Relay Switching Time 4mS including debounce
    Relay Configuration Form A, SPST Normally open

    HV15 Series Switch Card Configuration:

    HV15-8R 15KV Single input bus 8 output relays terminated in Red HV terminals,

    HV15-8B 15KV Single input bus 8 output relays terminated in Black HV terminals

    HV15-4R 15KV Single input bus 4 output relays terminated in Red HV terminals

    HV15-4B 15KV Single input bus 4 output relays terminated in Black HV terminals

    HV15-MX2 Dual input Single output MUX Card (selectable HV or continuity capability)

    HC-4 40 Amp High Current Source & Sense Switch Card

     

    Maximum Input Voltage 700 VDC, 50 VAC RMS
    Maximum Switching Voltage 277VAC, 30VDC
    Maximum Current 40A DC or RMS AC
    Relay Switching Power 500 Watts
    Card Configuration 4 channels of high current relays and 4 channels of sense relays
    Relay Configuration All Form A, SPST Normally open

    HC-4 High Current Switch Card Configuration:

    HC-4R 4 HC Source & 4 sense relays terminated in Red Terminals.

    HC-4B 4 HC Source & 4 sense relays terminated in Black Terminals.

     

    HC-7 70 Amp High Current Source & Sense Switch Card

    Maximum Input Voltage 700 VDC, 500 VAC RMS
    Maximum Switching Voltage 277VAC, 30VDC
    Maximum Current 70A DC or RMS AC
    Relay Switching Power 500 Watts
    Card Configuration 4 channels of high current relays and 4 channels of sense relays
    Relay Configuration All Form A, SPST Normally open

    HC-7 High Current Switch Card Configuration:

    HC-7R 4 HC Source & 4 sense relays terminated in Red Terminals.

    HC-7B 4 HC Source & 4 sense relays terminated in Black Terminals.

     

    General Specifications

    Switch Card Capacity Holds up to 7 switch cards
    High Voltage Terminals All HV terminals are 15KV rated and supplied with mating connector, optional HV leads sets available on request
    Remote Interface GPIB standard, RS232 optional
    Indicators L.E.D. status indicators for Test, Standby, Active, Talk, Listen, Address
    Diagnostics Built-in self diagnostics test ROM and RAM 
    Operating Temperature 0°C to 50°C
    Humidity 80% RH 0°C to 40°C
    Power 115/230 VAC +/- 10% VA max
    Dimensions 89mmH x 432mmW x 485mmD (3.5"H x 17"W x 19"D)
    Weight 12Kg (27 lb.) Net/16Kg (36 lb.) Shipping
    Standard Accessories Operator's manual, hipot connection test leads and power cord
    Warranty 1 year parts and labor
    Safety CE mark certified to EN61010

    Top of Page

    Prices listed in the table below are in US$ and apply to North American destinations only.  For inter-continental product destinations, please add 5% to the prices shown below.

    ID# Product Price $ Order
    948i High Voltage Scanning System (7 Card Capacity) $2,490.00
     Quantity
    HV7-8B 7KV Single Input Bus 8 Output Relays Terminated in Black HV Terminals 800.00
     Quantity
    HV7-8R 7KV Single Input Bus 8 Output Relays Terminated in Red HV Terminals 800.00
     Quantity
    HV7-4R 7KV Single Input Bus 4 Output Relays Terminated in Red HV Terminals 500.00
     Quantity
    HV7-4B 7KV Single Input Bus 4 Output Relays Terminated in Black HV Terminals 500.00
     Quantity
    HV7-MX2 Dual Input Single Output MUX Card (Selectable HV or Continuity Capability) 400.00
     Quantity
    HV10-8B 10KV Single Input Bus 8 Output Relays Terminated in Black HV Terminals 1,000.00
     Quantity
    HV10-8R 10KV Single Input Bus 8 Output Relays Terminated in Red HV Terminals 1,000.00
     Quantity
    HV10-4B 10KV Single Input Bus 4 Output Relays Terminated in Black HV Terminals 600.00
     Quantity
    HV10-4R 10KV Single Input Bus 4 Output Relays Terminated in Red HV Terminals 600.00
     Quantity
    HV10-MX2 Dual Input Single Output MUX Card (Selectable HV or Continuity Capability) 500.00
     Quantity
    HV15-8B 15KV Single Input Bus 8 Output Relays Terminated in Black HV Terminals 1,200.00
     Quantity
    HV15-8R 15KV Single Input Bus 8 Output Relays Terminated in Red HV Terminals 1,200.00
     Quantity
    HV15-4B 15KV Single Input Bus 4 Output Relays Terminated in Black HV Terminals 700.00
     Quantity
    HV15-4R 15KV Single Input Bus 4 Output Relays Terminated in Red HV Terminals 700.00
     Quantity
    HV15-MX2 Dual Input Single Output MUX Card (Selectable HV or Continuity Capability) 600.00
     Quantity
    QT-1 QuickTest Software 295.00
     Quantity
    GP-1 1 Meter Shielded GPIB Cable 85.00
     Quantity
    GP-2 2 Meter Shielded GPIB Cable 95.00
     Quantity
    RS-1 6' RS-232 Cable 45.00
     Quantity
    HC-7 4 Channel 70A Source & 4 Ch Sense Relay Card 700.00
     Quantity
    HC-4 4 Channel 30A Source & Sense Relay Card 500.00
     Quantity
    MC-1L HV Mating Connector with 4' HV Lead 25.00
     Quantity
    RM-1 Rack Mount Kit 75.00
     Quantity
    RS-232 Serial Com Port in lieu of GPIB 0.00
     Quantity
    OM-948 Additional Operator's Manual 35.00
     Quantity
    SPK-948 5 Year Spare Parts Kit 395.00
     Quantity

    Top of Page

    Rental Information

    30 Day Minimum.  Rates are for standard models. 
    Additional options are available. Please contact factory for a quote or for further assistance.
    DurationPriceBilling CycleBuyout
    30 Days $40030 DaysList Price minus 30% of Rental Paid
    60 Days$600/2 Months60 DaysList Price minus 40% of Rental Paid
    3 to 11 Months$300/Month30 DaysList Price minus 50% of Rental Paid
    12 Months$300/Month30 Days$1 Buyout

    Click  here to download the data sheet
    This document requires that you have the Adobe Acrobat reader which you can download for free here.

    Top of Page

    Home  |  Products  |  Services  |  Resources  |  Sales Offices  |  Price List 
    	  About  |  Contact  |  Support  |  Site Map 

    Copyright © 2009, All Rights Reserved