Performance
The new Vitrek V4 Hipot Electrical Safety Tester combines AC & DC Hipot with high current ground bond and insulation resistance testing, all in one feature rich, fully automated, easy to use instrument. This programmable Hipot tester provides test voltages up to 6KVDC and 5KVAC, programmable in 5V increments. As a Ground Bond Tester, it features up to 42 amps to test the integrity of the ground bond. As a high voltage Insulation Resistance tester the unit tests for Insulation Resistance Breakdown by providing 10 levels of HV trip points and provides 3 full scale measurements up to 10,000MΩ at 1000 volts.
The uncompromising performance of the V4 delivers fast, consistent, reliable results – test after test. And it does it from a single test connection. The V4’s crystal clear LCD user interface is remarkably easy to use and has all the information you need to get the job done right the first time.
Reliability
The uncompromising performance of the V4 delivers fast, consistent, reliable results – test after test. The V4’s crystal clear LCD user interface is remarkably easy to use and has all the information you need to get the job done right the first time. And the advanced reliability design of the V4 insures that it will remain on the job – day after day, year after year. World class manufacturers around the globe depend on Vitrek.
Economical
Vitrek’s V4 is a 4-in-1 Electrical Safety Compliance Tester incorporating High Voltage test capability for AC Hipot, DC Hipot, Insulation Resistance and high amperage test currents for ground bond continuity testing….. for about half the price you would expect to pay.  * International prices are approximately 5% higher than those listed below.
Â
|
-
5kVAC 40mA, 6kVDC 10mA
-
Ground Bond 3 to 42 Amps RMS
-
Multi-mode IR 50 to 1000V
-
SFIâ„¢ Safety Fault Interrupt
-
RS232 Standard, available GPIB
-
High Speed Discharge
-
36 Position Memory
-
Selectable Arc Detection
-
PLC Remote Interface
-
Three Year Extended Warranty*
AC Hipot
| Voltage Range: |
100 to 5000VAC RMS |
| Voltage Setting Resolution: |
5V/step |
| Voltage Regulation: |
1% of reading ± 5V |
| Voltage Accuracy: |
1% of reading ± 10V |
| Voltage Monitoring: |
At Output Terminals |
| Output Current: |
30mA to 40mA 180S max, 10 to 30mA continuous. Below 500V 10mA max |
| Min/Max Current Limits: |
0.1 to 40mA |
| Current Accuracy: |
1.5% of reading ± 50mA |
Â
DC Hipot
| Voltage Range: |
100 to 6000VDC |
| Voltage Setting |
Resolution: 5V/step |
| Voltage Regulation: |
1% of reading ± 5V |
| Voltage Accuracy: |
1% of reading ± 10V |
| Voltage Monitoring: |
At Output Terminals |
| Max Output Current: |
10mA continuous, below 500VDC 2mA continuous |
| Min/Max Current Limits: |
0.1 to 10mA |
| Current Accuracy: |
1.5% of reading ± 50mA |
Insulation Resistance
| DC Output Voltage: |
50, 100, 500 or 1000V |
| Resistance Range: |
1 to 9900MΩ |
|
Resistance Accuracy: (% of reading)
|
| 50, 100 VDC |
1-50MΩ 5% 51-200MΩ 10% 201-2000MΩ 20% |
| 500, 1000 VDC |
1-500MΩ 5% 501-2000MΩ 10% 2001-9900MΩ 20% |
| Multi-Mode IRâ„¢: |
Select 1 of 3 modes - Test passes on good reading, test fails on bad reading, pass/fail determined at end of test time. |
Â
Ground Bond/Continuity
| Test Current: |
3 to 42 Amps RMS |
| Terminal Configuration: |
4 wire Kelvin |
| Resistance Range: |
0 to 600mW |
| Resistance Resolution: |
100mW |
| Resistance Accuracy: |
1% reading ± 3mΩ |
| Compliance Voltage: |
8V at terminals |
| Current Resolution: |
0.01A |
| Voltage Resolution: |
0.01V |
Â
General
| Test Database: |
10 test sequences with up to 16 steps per test sequence |
| Front Panel Lockout: |
Prevents database edit while in lockout mode |
| Arc Detect: |
10 level trip select |
| Remote Interfaces: |
Fully interactive RS232 - standard. PLC Interface with Outputs of Testing, Pass, Fail and Inputs of Start, Reset - standard. Talk/Listen GPIB interface - Option GP-V4. |
| Timer Accuracy: |
0.25% ± 50mS |
| Power Source: |
100, 120, 220, 230VAC (±10% 50/60Hz), 350W max |
| Operating Environment: |
Indoor use, altitude up to 6500 ft (2000m). Installation Category II. Pollution Degree 2. |
| Operating Temperature: |
0°C to 40°C, 80% RH |
| Storage Temperature: |
-10°C to 70°C, 70% RH |
| Dimension: |
17.6"L x 13"W x 5.9"H, (446mmL x 330mmW x 149mmH) |
| Weight: |
33lbs (15kg) net, 40 lbs (18 kg) ship |
| Accessories |
NIST Cal Cert, TL-20-60 & K-2 Test Leads, Power Cord, Serial Interface Cable & User's Manual |
| Accuracy: |
Stated specifications apply for 1 year at 23°C ± 5°C. |
| Calibration: |
ANSI/NCSL Z540 Certificate of Calibration with Data provided, traceable to NIST. |
| Compliance: |
CE Mark Certified to EN61010 and EMC Directives EN50081-1 & EN50082-2. |
| Warranty: |
* 3 Year Extended Warranty with registration and annual factory calibration. 1 year parts and labor standard. |
QuickTestâ„¢ Software
| Option QT-V4: |
Bundled Test Automation Software and PC Serial Interface Cable. Easy to load graphical test sequence development and operating environment. Provides time/date, operator, test parameters, test results and readings. Results may be viewed, printed out or exported to a database program. |
Â
30 Day Minimum. Rates are for standard models. Additional options are available. Please contact factory for a quote or for further assistance.
| Duration |
Price |
Billing Cycle |
Buyout |
| 30 Days |
$530 |
30 Days |
List Price minus 30% of Rental Paid |
| 60 Days |
$800/2 Months |
60 Days |
List Price minus 40% of Rental Paid |
| 3 to 11 Months |
$400/Month |
30 Days |
List Price minus 50% of Rental Paid |
| 12 Months |
$400/Month |
30 Days |
$1 Buyout |
In order to better assist you in the future, we would like to get some basic information from you before you download any of our Manuals. We respect your right to privacy and do not and will not ever share this information with any third party. Please review our privacy policy for more information.
|