4700 Precision High Voltage Meter
Measurement integrity is our bottom line – whether you are on a production line manufacturing high voltage medical imaging equipment, in a national laboratory conducting ground breaking research or in the cal lab certifying test equipment, it is essential
| |||||||||||||||||||||
|
The new Vitrek 4700 Precision High Voltage Meter offers the highest level of measurement accuracy, yet is surprisingly easy to use. Vitrek has harnessed DSP technology to provide outstanding AC &DC voltage accuracy, stability and resolution. Performance that rivals traditional HV reference dividers, yet unlike the delicate HV divider, the 4700 provides instant, direct, high voltage measurements in a highly portable, compact and rugged bench top enclosure. The 4700's large, high resolution, color, touch graphic display simultaneously shows the AC and DC content of the voltage being measured and can plot readings from a few seconds to several days. |
|||||||||||||||||||||
The new Vitrek 4700 Precision High Voltage Meter offers the highest level of measurement accuracy, yet is surprisingly easy to use. Vitrek has harnessed DSP technology to provide outstanding AC &DC voltage accuracy, stability and resolution. Performance that rivals traditional HV reference dividers, yet unlike the delicate HV divider, the 4700 provides instant, direct, high voltage measurements in a highly portable, compact and rugged bench top enclosure. The 4700's large, high resolution, color, touch graphic display simultaneously shows the AC and DC content of the voltage being measured and can plot readings from a few seconds to several days.
Direct Measurement or SmartProbe™ - You Make the Call
Vitrek's 4700 precisely measures voltages directly up to 15KV, right out of the box - with no external probes. That's high enough for 90% of the HV sources out there, however, should you care to expand your high voltage measurement range - just add one or more of the available 35KV, 70KV and 100KV SmartProbes™. The Vitrek SmartProbes™ each store their own calibration data which is down loaded when they are plugged in to the 4700 - this results in high accuracy, calibrated readings and allows any Vitrek SmartProbe™ to be used with any 4700 HV Meter. The SmartProbe's™ proprietary, ultra low TC attenuator design eliminates voltage coefficient adders - while its reduced capacitive construction technology enhances AC performance. In addition to the direct input terminal the 4700 has two probe inputs - use one probe to extend your measurement range or use two probes for making high voltage differential measurements.
2
Superior Performance by Design
Measurement integrity is our bottom line – whether you are on a production line manufacturing high voltage medical imaging equipment, in a national laboratory conducting ground breaking research or in the cal lab certifying test equipment, it is essential to choose your tools carefully. To insure the best possible measurement accuracy, the 4700 makes over 40,000 reading per second which are then filtered, sub-sampled, scaled and offset corrected - all with "error free" mathematic methodology. The True RMS AC readings are as true as they come, while the DC measurements offer rocket fast settling with rock solid stability. In addition to this, the 4700 provides VLF AC readings down to 0.01 Hz, as well as, peak to peak, crest factor and fundamental frequency measurement.
High Voltage Test Automation
Automate your HV test requirement with the 4700's built-in Ethernet port, high speed serial communication port or available GPIB. The 4700 is fully programmable - so you can select your measurement mode and bandwidth, then take readings as often as desired. The 4700 also comes standard with a USB printer port, to capture readings and get hardcopy printouts of HV plots - so you can document the sag or overshoot in a typical hipot test.
Performance Specifications 4700 Direct Input Measurement Maximum Input Voltage 15KV DC, 10KV AC RMS, 15KV peak (110MΩ input impedance) Voltage Measurement Accuracy (1 year ±3°C from cal temperature) DC Voltage 0.03% of reading + 0.03V + ½ digit AC Volts (Band Selectable) 0.01 to 1Hz : 0.1% of reading + 0.1V + ½ digit 1 to 2Hz : 0.4% of reading + 0.1V + ½ digit 10 to 65Hz : 0.1% of reading + 0.1V + ½ digit 30 to 200Hz : 0.1% of reading + 0.2V + ½ digit 200 to 450Hz : 0.6% of reading + 0.2V + ½ digit 450 to 600Hz : 1.25% of reading + 0.2V + ½ digit Ripple Measurement 30 to 600Hz : 2% of reading + 0.3V + ½ digit Measurement Resolution DC & AC Measurements 0.01V to 400VDC/pkAC, 0.1V to 4KVDC/pkAC, 1V above 4KV 4700 SmartProbe™ Input Measurement Maximum Input Voltages HVL-100 Probe 100KVDC, 100KV AC RMS, 150KV peak (600MΩ input impedance) HVL & HVP-70KV Probes 70KVDC, 70KV AC RMS, 100KV peak (400MΩ input impedance) HVL & HVP 35KV Probes 35KVDC, 35KV AC RMS, 50KV peak (200MΩ input impedance) Voltage Measurement Accuracy (1 year ±3°C from cal temperature) DC Voltage HVL-100: .05% of reading + 0.3V + ½ digit HVL-70: .04% of reading + 0.2V + ½ digit HVP-70: .05% of reading + 0.2V + ½ digit HVL-35: .03% of reading + 0.07V + ½ digit HVP-35: .04% of reading + 0.07V + ½ digit AC Volts (Band Selectable) HVL-100 0.01 to 1Hz : 0.3% of reading + 0.6V + ½ digit 30 to 100Hz : 0.12% of reading + 0.6V + ½ digit 200 to 450Hz : 2.5% of reading + 0.6V + ½ digit HVL-70 0.01 to 1Hz : 0.25% of reading + 0.4V + ½ digit 30 to 100Hz : 0.1% of reading + 0.4V + ½ digit 200 to 450Hz : 2.5% of reading + 0.4V + ½ digit HVP-70 0.01 to 1Hz : 0.3% of reading + 0.4V + ½ digit 30 to 100Hz : 0.12% of reading + 0.4V + ½ digit 200 to 450Hz : 2.5% of reading + 0.4V + ½ digit HVL-35 0.01 to 1Hz : 0.12% of reading + 0.2V + ½ digit 30 to 200Hz : 0.09% of reading + 0.2V + ½ digit 200 to 450Hz : 0.6% of reading + 0.2V + ½ digit 4 HVP-35 0.01 to 1Hz : 0.15% of reading + 0.2V + ½ digit 30 to 200Hz : 0.1% of reading + 0.2V + ½ digit 200 to 450Hz : 0.6% of reading + 0.2V + ½ digit High Voltage Self Heating This is the effect of self heating induced as a result of voltage on the DIRECT terminal. This effect is not included in the accuracy specifications above, takes up to several minutes to become fully apparent and a similar time to dissipate. DC & ≥20Hz <2.5ppm of reading per KV2 <20Hz <3.5ppm of reading per KV2 KV = total RMS (DC+AC) voltage expressed in KV and <0.1% at 400Hz when placed 18” from the probe. As long as objects do not move relative to the probe, there is negligible effect on DC measurements caused by nearby objects. Objects generating fields may need to be placed further away from the probe than these figures. High Voltage Self Heating This is the effect of self heating induced as a result of voltage on the probe input. This effect is not included in the accuracy specifications above, takes up to several minutes to become fully apparent and a similar time to dissipate. DC & ≥20Hz <0.75ppm of reading per KV2 <20Hz <1.25ppm of reading per KV2 KV = total RMS (DC+AC) voltage expressed in KV PRECISE Mode (1-75Hz Band Selection) 1 to 35Hz : <0.3% of reading + 0.4V + ½ digit 35 to 75Hz : <0.6% of reading + 0.4V + ½ digit PRECISE Mode (0.1-35Hz Band Selection) 0.1 to 15Hz : <0.3% of reading + 0.4V + ½ digit 15 to 35Hz : <0.6% of reading + 0.4V + ½ digit PRECISE Mode (0.01-2Hz Band Selection) RIPPLE Mode 30 to 450Hz : <2.5% of reading + 0.6V + ½ digit FAST Mode 45 to 100Hz : <0.15% of reading + 0.6V + ½ digit 100 to 200Hz : <0.6% of reading + 0.6V + ½ digit 200 to 450Hz : <2.5% of reading + 0.6V + ½ digit DC Rejection >65dB, except RIPPLE mode which is >100dB Common Mode Error <0.05% + (0.025% times frequency in Hz) of the COMMON terminal AC voltage Pk-Pk Measurement 4V + 2*AC accuracy + ½ digit Crest Factor Measurement 0.001 + ((2V + AC Accuracy) / AC Signal Level) + ½ digit Frequency Measurement AC signal >(15Vrms + 2% of DC signal) : <0.02% (<0.05% in FAST Mode) + ½ digit High Voltage Self Heating This is the effect of self heating induced as a result of voltage on the probe input. This effect is not included in the accuracy specifications above, takes up to several minutes to become fully apparent and a similar time to dissipate. DC & ≥20Hz <0.25ppm of reading per KV2 5 <20Hz <0.4ppm of reading per KV2 KV = total RMS (DC+AC) voltage expressed in KV 30 Day Minimum. Rates are for standard models. Additional options are available. Please contact factory for a quote or for further assistance.