Technology Leaders in Electrical Safety Compliance Test Equipment      
About Vitrek  |  Contact  |  Site Map       View Cart  |  Check Out  | 
OUR PRODUCTS

950i Electrical Safety Compliance Analyzer



REQUEST A CATALOGUE

Hipot & Electrical Safety Tester Selection Guide      

 
Model V4 944i V63 V61 V60 930i V5
Functions AC & DC Hipot, Insulation Resistance, Ground Bond  AC & DC Hipot, Insulation Resistance, Ground Continuity  AC & DC Hipot, Insulation Resistance, Ground Continuity  AC & DC Hipot,  Ground Continuity AC  Hipot, Ground Continuity  Ground Bond (GB) AC & DC Hipot, Insulation Resistance, G B & HV Scanner
AC Hipot Dielectric Breakdown 5KV RMS Max
40mA Max
10uA Resolution
50-60 Hz
5KV RMS Std,
8KV optional
35mA Max
10nano A Res.
40-100Hz
5KV RMS Max
40mA Max
10uA Resolution
50-60 Hz
5KV RMS Max
40mA Max
10uA Resolution
50-60 Hz
5KV RMS Max
40mA Max
10uA Resolution
50-60 Hz

-

5KV RMS Max
40mA Max
10uA Resolution
50-60 Hz
DC Hipot Arc Detection 6KVDC, megger
10 mA max
10μA Resolution
5KVDC Std,
7 & 10KVDC
option
35 mA max
1nano A resolution
6KV,
10 mA max10μA Resolution
6KVDC,
10 mA max
10μA Resolution
- - 6KVDC,
10 mA max
10μA Resolution
IR
 (Insulation
Resistance) Voltage Withstand

 

10GΩ max
50, 100, 500, 1000VDC
Multi-mode
100GΩ
100-5000V std
10-99V optional
Multi-mode
10GΩ max
50, 100, 500, 1000VDC
Multi-mode
- - - 10GΩ max
50, 100, 500, 1000VDC
Multi-mode
Ground Bond &
Ground Continuity
Ground Bond
3-42A, 4-wInsulation Resistance
e
100μΩ res.
Ground Continuity, 50mA
1mΩ to 8Ω std
1mΩ to 1kΩ opt.
Ground Continuity
100mA 2-wInsulation Resistance
e
10mΩ to 1.5Ω

Ground Continuity
100mA 2-wInsulation Resistance
e
10mΩ to 1.5Ω

Ground Continuity
100mA 2-wInsulation Resistance
e
10mΩ to 1.5Ω

Ground Bond
3-30A, 4-wInsulation Resistance
e
40A optional
Ground Bond
3-42A, 4-wInsulation Resistance
e
100μΩ res.
Test
Memory
10 positions
Up to 16 steps ea
40 Positions
200 steps total
10 positions
Up to 16 steps ea

10 positions
Up to 16 steps ea

10 positions
Up to 16 steps ea

10 Position

10 positions
Up to 16 steps ea
Arc Detection Selectable
1-40mA
Selectable
1μS, 10μS, 30μS
Selectable
1-40mA

Selectable
1-40mA

Selectable
1-40mA

- Selectable
1-40mA
Safety fault Interrupt Std Optional Std

Std

Std

- Optional
Special
Features
Digital setup,
Displayed results,
Auto cal
Line & load reg
Same as others,
Plus:
Ramp Down, Dual Ramp & dwell limits
Digital setup,
Displayed results,
Auto cal
Line & load reg

Digital setup,
Displayed results,
Auto cal
Line & load reg

Digital setup,
Displayed results,
Auto cal
Line & load reg

Digital setup,
Displayed results,
Auto cal
Line & load reg

Digital setup,
Displayed results,
Auto cal
Line & load reg
Interfaces RS232, PLC & Scanner control std
GPIB IEEE-488 optional
RS232, PLC, GPIB IEEE-488
Printer port optional
RS232, PLC & Scanner control std
GPIB IEEE-488 optional

RS232, PLC & Scanner control std
GPIB IEEE-488 optional

RS232, PLC & Scanner control std
GPIB IEEE-488 optional

RS232 & VICL
Standard

RS232, PLC & Scanner control std
GPIB IEEE-488 optional
Failure indications Audible & Visual Audible & Visual Audible & Visual Audible & Visual Audible & Visual Audible & Visual Audible & Visual
Rackmount/
Rear Output
Optional
Standard
Optional
Optional
Optional
Optional
Optional
Optional
Optional
Optional
Optional
Standard
Standard
Standard

Home  |  Products  |  Services  |  Resources  |  Sales Offices  |  Price List
About  |  Contact  |  Support  |  Site Map

Copyright © 2009 , All Rights Reserved